Supplier Homepage Offer AC Drives F2000-P Fan and Pump Series (0.75-450KW)
F2000-P Fan and Pump Series (0.75-450KW)
Offer Type:two sell
Offer Group: AC Drives
Offer Post Time:Jan 18,2017
Expiration Date:Jan 18,2018

Details

With advanced functions of Time Period Control and PID adjusting. The running mode has single-pump mode, fixed mode of 1 drive controlling 2 pumps, rotating mode of 1 drive controlling 2 pumps, fixed mode of 1 drive controlling several pumps and rotating mode of 1 drive controlling several pumps. F2000-P series are effectively applied on the field of fan and pump loads.

Main function
Single-pump mode: 1 drive controls one pump by PI adjusting.
Fixed mode of 1 drive controlling n pumps: 1 drive controls n pumps. One pump controlled by AC drives is called as frequency-conversion pump. The drive controls frequency-conversion pump by PI adjusting. The other pumps are connected with commercial power supply. The starting or stopping of these pumps are controlled by AC drives. These pumps are called as pumps of commercial power supply.
Interchanging mode of 1 drive controlling n pumps: N pumps are interchanged to connect with the drive for a fixed period of time. After the interchanging time, frequency-conversion pump will be changed to pump of commercial power supply, and one pump of commercial power supply will be changed to the frequency-conversion pump.
Circulating mode of 1 drive controlling n pumps: AC drives start or stop water pumps circularly according to PID feedback pressure. First start one pump, then stop one pump.
Several speed control modes: PID adjusting, jogging control, analog control, digital setting control, PC/PLC control by MODBUS, and so on.
The function of starting and stopping pumps controlled by different time period: Users can set at most 6 time periods to control pumps started or stopped.
Stage speed control in different time period: Users can set at most 6 time periods of stage speed.
Two-line type, three-line type operation control: Terminal speed control is more convenient.
Other functions: DC braking, rich displaying functions (In the stopping status, pressure value and present sensor input value are displayed by switching over mode. When clock function is on, present time can be displayed) and conversion function of daylight saving time.


 
Items Contents
Input Voltage Range 3-phase 400V±15%;
Frequency Range 50/60Hz
Output Voltage Range 3-phase 0-400V
Frequency Range 0.00-60.0Hz (Frequency resolution is 0.01Hz )
Control
Mode 
Carrier Frequency 1600-10000Hz; random carrier frequency
Input Frequency Resolution Digital setting: 0.01Hz, analog setting: max frequency 0.1%
Control Mode V/F control
Overload Capacity 120% rated current, 60 seconds, 150% rated current, 10 seconds.
Torque Elevating Manual Torque Promotion 0.1%-30.0%  (V/F)
V/F Curve 3 kinds of modes: beeline type, square type and under-defined V/F curve.
DC Braking DC braking frequency: 1.0-5.0 Hz, braking time: 0.0-10.0s
Automatic Voltage Rectification (AVR) Enable to keep output voltage constant automatically in the case of change of grid voltage.
Operation Function Frequency Setting Potentiometer or external analog signal; keypad (terminal) up/down keys, external control logic and auto-circulating setting, PC/PLC setting.
Start/Stop Control Terminal control, keypad control or PC/PLC control.
Running Command Channels 3 kinds of channels from keypad panel, control terminal and PC/PLC.
Frequency Source Given digit, given analog voltage, given analog current, given PC/PLC, PI adjusting and stage speed control.
Accessorial frequency Source Given digit, given analog voltage, given analog current, PI adjusting and stage speed control.
Protection Function Input out-phase, input under-voltage, over-voltage, over-current, AC drives over-load, motor over-load, over-heat, motor detection fault, external equipment fault, external disturbance, water lack protection, pressure protection, line disconnection protection.
Display LED nixie tube showing present output frequency, present time, present flow of water, present output current, present output voltage, types of faults and parameters; Four LED indicators showing the current working status of AC drives.
Environment Conditions Equipment Location In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc.

 
Environment Temperature -10 degree-+50 degree

 
Environment Humidity Below 90% (no water-bead coagulation)

 
Vibration Strength Below 0.5g (acceleration)

 
Height above sea level 1000m or below
Applicable Motor 0.75-450KW